House No. 2

Back to select a different house
+

House No.2

Overall performance

Comfort i

1.4

18 cm 20 cm
House 2 is comparable with house 1 in terms of the wall structure, although the internal coating has a high absorption capacity.

The high thermal capacity offers protection from summer overheating. The interior plaster means there is little fluctuation of the inner surface temperature. Due to its interior plaster, house 1 has a much higher moisture penetration coefficient than house 2. The substantial improvement in the humidity caused by this was also verified experimentally within the research houses.

House description

Wall material

Concrete

Wall thickness

18 cm

Inner plaster

Inner coating (paint)

Ionit

Insulation

Insulation thickness

20 cm

Building physical parameters

Protection against overheating in the summer i

Heat storage i

Humidity i

Fluctuation of the inner surface temperature i

Physical parameters

Sound proofing

Room acoustics

Absorption of high frequency electromagnetic fields

Noticeable Odour

Temperature parameters i

Summer

Outside temp.

36 °C

Inner temp.

25 °C

Winter

Outside temp.

-12 °C

Inner temp.

17 °C

Wall temp. in plaster

17 °C

Sound

Sound insulation

49 dB

Subjective feelings of houses visitors

Detectable odour i

Room acoustics i

Air quality i